Technical Specifications
Remote Specifications
On/Off
Disables sensor; light is permanently* on or off. *un-do permanent on/off by selecting either Auto-Mode, RESET, or any Scene mode button.
Auto Mode
Sensor acticates and all previously selected settings remain programmed
RESET
Overrides selected settings; reverts to DIP settings
Dim Buttons
"+" dims up and "-" dims down, adjusting lamp brightness
Test 2s
Automatic* test mode with 2 second time delay; disables cut off period and daylight sensor. *Un-do automatic test mode by selecting either RESET, any Scene mode button, or hold time.
Power 100% & Power 80%
Adjusts power output; to save energy select Power 80%. Must return to full output after initial 10,000 hours of LEDs by pressing Power 100%.
Detection Range Button Group
Assigns the detection range of 10, 50 or 100%. To limit area in which motion will set off sensor, use a smaller percent. The sensor will not detect motion outside of 100% and the fixture will not light.
Time Delay Button Group
Assigns hold time of 30 seconds, 1 minute, 5 minutes, 10 minutes, or 30 minutes
Cut Off Button Group
Assigns cut off period of 0 seconds, 10 seconds, 1 minute, 10 minutes, 30 minutes, or 1 hour. 0 seconds gives fixture on/off control rather than dimmingKeeps the light on always (if daylight sensor is disabled)
with Bi-Level dimming control.
Dim Level
Assigns level of 10, 20, or 30% for dimmed light output after time delay passes
Other
Buy American Act Compliance
RAB values USA manufacturing! Upon request, RAB may be able to manufacture this product to be compliant with the Buy American Act (BAA). Please contact customer service to request a quote for the product to be made BAA compliant.