Two flip logic prevents activation by momentary power outages. Override resets to auto after 6 hours or at dawn. No extra wiring needed.
Surge Protection
Withstands up to 3000 volts
Switching Capacity
300W incandescent @ 120 volts, 2.5 amps.
Sensor Specifications
Time Adjustment
8 seconds to 10 minutes
Photo Control
Deactivates lights during daylight. Fully adjustable for 24 hour operation or custom applications.
Detector Sensitivity
Adjustable from 100% to 50%
Auto Test Logic
5 minutes of test time when powered. Resets to auto mode without adjustment.
Sensor Housing
Made of tough, corrosion resistant polycarbonate
Detection
110° view
Construction
Floodlights
Made of tough, corrosion-resistant polycarbonate. Accepts PAR-38 lamps, medium base, 150W max. Lamps not included.
Other
Warranty
3-year sensor warranty
Buy American Act Compliance
RAB values USA manufacturing! Upon request, RAB may be able to manufacture this product to be compliant with the Buy American Act (BAA). Please contact customer service to request a quote for the product to be made BAA compliant.