Technical Specifications
Compliance
UL Listed
Suitable for damp locations
IESNA LM-79 & LM-80 Testing
RAB LED luminaires have been tested by an independent laboratory in accordance with IESNAlm-79 andlm-80
DLC Listed
This product is listed by Design Lights Consortium (DLC) as an ultra-efficient premium product that qualifies for the highest tier of rebates from DLC Member Utilities. Designed to meet DLC 5.1 requirements.
DLC Product Code: S-R1IK8X
Electrical
Driver
30W: Class 2, Constant Current, 120-277V, 50/60 Hz, 120V: 0.25A, 208V: 0.15A, 240V: 0.13A, 277V: 0.11A
25W: Class 2, Constant Current, 120-277V, 50/60 Hz, 120V: 0.21A, 208V: 0.12A, 240V: 0.10A, 277V: 0.10A
18W: Class 2, Constant Current, 120-277V, 50/60 Hz, 120V: 0.15A, 208V: 0.09A, 240V: 0.08A, 277V: 0.07A
Dimming Driver
Driver includes dimming control wiring for 0-10V dimming systems. Requires separate 0-10V DC dimming circuit. Dims down to 10%.
THD
3.41% at 120V, 4.37% at 277V
Power Factor
99.67% at 120V, 96.3% at 277V
Battery Backup
Battery backup will operate the fixture for 90 minutes if power fails. Wired for 120.
Max Mounting Height
Max 13.1 ft height
Detection Range
26.2 ft diameter at 13.1 ft height
Construction
Housing
Steel sheet metal
Cold Weather Starting
The minimum starting temperature is -20°C (-4°F)
Ambient Temperature
Suitable for use in up to 40°C (104°F)
Reflector
High-reflectance, powder-coated finish, optimized for uniform light distribution
Finish
Formulated for high durability and long-lasting color
Green Technology
Mercury and UV free. RoHS-compliant components.
LED Characteristics
LEDs
Long-life, high-efficacy, surface-mount LEDs
Color Stability
LED color temperature is warrantied to shift no more than 200K in color temperature over a 5-year period
Color Uniformity
RAB's range of Correlated Color Temperature follows the guidelines of the American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products, ANSI C78.377-2017.
Installation
Mounting
Retrofits into the existing housing
Performance
Lifespan
100,000-Hour LED lifespan based on IES LM-80 results and TM-21 calculations
Lightcloud
Lightcloud Blue
Lightcloud Blue is a Bluetooth Mesh wireless lighting control system that allows you to control RAB's various compatible devices. With RAB's patented Rapid Provisioning technology, devices can be quickly and easily commissioned for residential and large commercial applications using the Lightcloud Blue mobile app. Each device in a system can communicate with any other device, eliminating the need for a Gateway or Hub and maximizing the control system's reach.
DLC system - N1XMLOEATBA (Interior); NHCZ2BIA17L (Exterior)
Learn more at www.lightcloud.com.
Communication Protocol
Bluetooth Mesh
Range
Up to 60 ft between standard building materials. Up to 200 ft clear line of sight.
Spacing Criteria
Lightcloud Blue devices should be placed within the specified range to communicate within the Bluetooth Mesh network.
Factory Reset
To reset the device to factory settings and into pairing mode locate the device identification button at the top of the Controller under the Lightcloud logo. Press and hold this button for 10s or until the indicator light begins flashing red. If the Controller is attached to a fixture, the fixture will also flash on/off 5x.
Device Identification Button
Located at the top of the controller under the Lightcloud logo.
Once the Controller has been provisioned to the Lightcloud Blue mobile app this button offers the following functionality:
Press once to rapid identify this device in the Lightcloud Blue mobile app
Press twice to toggle circuit on and off
Press twice and hold to set dim level
Press and hold for 10s to reset the device to factory settings and into pairing mode
Sensor Settings
Default Setting
Uncommissioned State:
Sensor Status: Enabled
Motion Sensitivity: High
Brightness when triggered: 100%
Hold time: 1 minute
Standby to dim: 20%
Standby time: 1 minute
When vacant: Off
Commissioned State:
Sensor Status: Disabled, once enabled the following default are set.
Motion Sensitivity: High
Brightness when triggered: Last on status
Hold time: 20 minutes
When vacant: Off
Sensing Type
Occupancy or Vacancy
Sensor Sensitivity
Low/Medium/High
Occupied Actions
On or On at a Dim Level
Vacant Options
Off or On at a Dim Level
Occupancy Timeout
1 minute to 240 minutes
Daylight Sensing
The sensor will determine to trigger the light(s) on or not based on the daylight threshold level set in the Lightcloud Blue mobile app.
Daylight Threshold
150 lux to 1500 lux
Other
5 Yr Limited Warranty
The RAB 5-year, limited warranty covers light output, driver performance and paint finish. RAB's warranty is subject to all terms and conditions found at
rablighting.com/warranty.