Technical Specifications
Compliance
UL Listed
Suitable for wet locations
Other
Compatibility
Compatible with most electronic ballasts. Not compatible with instant start ballasts.
Warranty
5-year sensor warranty
Electrical
Manual Override
Double flip wall switch logic prevents activation by brief power outages. Resets after 6 hours. No extra wiring needed.
Surge Protection
Withstands up to 3000 volts
RF Immunity
Circuits fully shielded for maximum radio frequency immunity
Incandescent Watts Switched
500W @ 120 volts
Fluorescent Watts Switched
250W @ 120 volts
Power Consumption
Negligible
Switching Capacity
Relay On/Off Model Switches 240W when lights are mounted to sensor. 500W Incandescent or 240W Fluorescent of remotely mounted lighting @ 120 volts.
Sensor Settings
Time Adjustment
5 seconds to 15 minutes
Quick Test Time
5 second test time for fast installation. Works day or night.
"No Hands" Auto Testing
Auto mode starts after 4 minutes of testing. No adjustment needed.
Photoelectric Control
Deactivates lights during daylight.
Time Delay
5 seconds to 15 minutes
Ambient Light Sensing
Adjustable
Adjustments
Time, ambient light & sensitivity
Detection
180° detection pattern
LED Characteristics
LED Detection Indicator
LED glows red day & night for "on guard" deterrence