Technical Specifications
  
              
        
        
          
            Installed with Lightcloud
           
          
              Lightcloud is a commercial wireless lighting control system fully developed and supported by RAB. It's powerful and flexible, yet easy to use and install.
              
                  Learn More 
              
           
         
        
            Lightcloud
                
          
            Lightcloud Controller Installed
          
          
            Integrated/embedded networked lighting control, luminaire-level lighting control.  Fixture, Zone, and plug-load control from one powerful device. LLLC - capable of switching, 0-10Vdimming, power/energy monitoring. Can also be used to extend the range of the Lightcloud mesh network communication protocols. Offers the capability to set the maximum light output to a less-than-maximum state of an individual luminaire at the time of installation or commissioning. The High-End trim functionality is field reconfigurable via the Lightcloud mesh network communication protocols.  The Lightcloud controller can be attached to the fixture, junction box, or electrical panel.
 DLC system - NHCZ2BIA17L
 Learn more at www.lightcloud.com
           
                    Compliance
                
          
            UL Listed
          
          
            Suitable for wet locations
          
         
                
          
            IP Rating
          
          
            Ingress protection rating of IP66 for dust and water
          
         
                
          
            IESNA LM-79 & LM-80 Testing
          
          
            RAB LED luminaires and LED components have been tested by an independent laboratory in accordance with IESNA LM-79 and LM-80.
          
         
                    Construction
                
          
            IES Classification
          
          
            The Type II distribution is ideal for wide walkways, on ramps and entrance roadways, bike paths and other long and narrow lighting applications. This type is meant for lighting larger areas and usually is located near the roadside. This type of lighting is commonly found on smaller side streets or jogging paths.
          
         
                
          
            Maximum Ambient Temperature
          
          
            Suitable for use in up to 104°F (40°C)
          
         
                
          
            Cold Weather Starting
          
          
            The minimum starting temperature is -40°F (-40°C)
          
         
                
          
            Thermal Management
          
          
            Superior heat sinking with external Air-Flow fins
          
         
                
          
            Housing
          
          
            Die-cast aluminum with airflow fins for cooling
          
         
                
                
          
            Reflector
          
          
            Vacuum-metalized polycarbonate
          
         
                
          
            Gaskets
          
          
            High-temperature silicone gaskets
          
         
                
          
            Finish
          
          
            Formulated for high durability and long-lasting color
          
         
                
          
            Green Technology
          
          
            Mercury and UV free. RoHS-compliant components.
          
         
                    LED Characteristics
                
          
            LEDs
          
          
            Multi-chip, high-output, long-life LEDs
          
         
                
          
            Color Consistency
          
          
            3-step MacAdam Ellipse binning to achieve consistent fixture-to-fixture color
          
         
                
          
            Color Stability
          
          
            LED color temperature is warrantied to shift no more than 200K in color temperature over a 5-year period
          
         
                
          
            Color Uniformity
          
          
            RAB's range of Correlated Color Temperature follows the guidelines of the American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products, ANSI C78.377-2017.
          
         
                    Electrical
                
          
            Driver
          
          
            Constant Current, Class 2, 120-277V, 50/60Hz, 120V: 2.21A, 208V: 1.25A, 240V: 1.09A, 277V: 0.97A
          
         
                
          
            Dimming Driver
          
          
            Driver includes dimming control wiring for 0-10V dimming systems. Requires separate 0-10V DC dimming circuit. Dims down to 10%.
          
         
                
          
            THD
          
          
            6.65% at 120V, 8.84% at 277V
          
         
                
          
            Power Factor
          
          
            99.8% at 120V, 96.7% at 277V
          
         
                
                    Optical
                
                    Other
                
          
            5-Year, No-Compromise Warranty
          
          
            RAB warrants that our LED products will be free from defects in materials and workmanship for a period of five (5) years from the date of delivery to the end user, including coverage of light output, color stability, driver performance and fixture finish. RAB's warranty is subject to all terms and conditions found at 
rablighting.com/warranty.
           
                
          
            Patents
          
          
            The WPLED design is protected by patents pending in the U.S., Canada, China, Taiwan and Mexico.
          
         
                    Performance
                
          
            Wattage Equivalency
          
          
            Equivalent to 750W Metal Halide