Technical Specifications
Compliance
UL Listed
Suitable for wet locations
Construction
Compatibility
Compatible with most electronic ballasts. Not compatible with instant start ballasts.
Electrical
Manual Override
Double flip wall switch logic prevents activation by brief power outages. Resets after 6 hours. No extra wiring needed.
Surge Protection
Withstands up to 3000 volts
RF Immunity
Circuits fully shielded for maximum radio frequency immunity
Incandescent Watts Switched
500W @ 120 volts
Fluorescent Watts Switched
250W @ 120 volts
Power Consumption
Negligible
Switching Capacity
Relay On/Off Model Switches 240W when lights are mounted to sensor. 500W Incandescent or 240W Fluorescent of remotely mounted lighting @ 120 volts.
Sensor Specifications
Time Adjustment
5 seconds to 15 minutes
Quick Test Time
5 second test time for fast installation. Works day or night.
"No Hands" Auto Testing
Auto mode starts after 4 minutes of testing. No adjustment needed.
Photoelectric Control
Deactivates lights during daylight. Fully adjustable for 24 hour operation or custom applications.
Time Delay
5 seconds to 15 minutes
Ambient Light Sensing
Adjustable
Adjustments
Time, ambient light & sensitivity
Detection
180° detection pattern
LED Characteristics
LED Detection Indicator
LED glows red day & night for "on guard" deterrence
Other
Warranty
5-year sensor warranty
Buy American Act Compliance
RAB values USA manufacturing! Upon request, RAB may be able to manufacture this product to be compliant with the Buy American Act (BAA). Please contact customer service to request a quote for the product to be made BAA compliant.